Update
Applications
Advantages:
For developer:
(Пайпы программ) Companies:
History:
(Бонусы) Advice:
(Барьеры и решения) Technologies:
(Применение в науке, лаборатории, ..)
Solutions
New eComStation:
Future:
(Ссылки на другие сайты) (Картинка дня) OS/2 artefacts:
Gadgets:
|
Attansic L1 Gigabit
Mark: Good (the report is combined by ecomstation.ru)
I have a motherboard with an Attansic L1 Gigabit Ethernet chip and have
it working using Genmac220. When I first installed it the link lights
on the switch showed it running at a 1000Mhz but now it only runs at
10Mhz. When the PC is first switched on POST sets the lights to 1000
but once the driver loads they go to 10 again.
I've tried inserting "HKR_MediaType,6" into the options field of
PROTOCOL.INI in an attempt to force 1000 but it doesn't make any
difference.
>> Is that how you force options?
>> Any other ideas?
>
>I'd try editing ATL01_XP.INF instead, on line 44. The "auto" setting
>should work, though. What's it connected to?
I looked at that file and it had the media type set to 1 at the top and
to 0 further down. I changed the top one to 0 and it now running at
1000 :-)
Information is sent by: Rodney Pont -- 2008-10-16 01:35:05
****************************************
[GoogleAdv]
Test the program:
|
eSchemes - change the colors and buttons on the desktop.
|
eCo Software is participating in the conferences.
We made more than 15 presentations.
We published more than 10 reports.
|
Ideas for the developers:
|
DevCon: Library of REXX scripts. Share useful scripts with other users.
|
|
|
IBM OS/2 Warp
|
|